SCHNEIDER Electric - TeSys D Contactor, 3P, 40A, AC-3 440V, aux 1NO+1NC, 230V, 50Hz, EverLink

Lei 341.00 Lei 286.55
In stock
Only 8 left
SKU
LC1D40AP5
Free shipping for orders over 500 lei
Free shipping applies to cities without additional kilometers or heavy/high volume products

Documents & Downloads:

Product datasheet RO

Catalogue

Write Your Own Review
You're reviewing:SCHNEIDER Electric - TeSys D Contactor, 3P, 40A, AC-3 440V, aux 1NO+1NC, 230V, 50Hz, EverLink
More Information
Manufacturer SCHNEIDER Electric
Manufacturer code LC1D40AP5
Order Unit Pce
Range TeSys; TeSys Deca
Product Name TeSys D; TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control; Resistive load
Utilisation category

AC-4
AC-1
AC-3
AC-3e

Power pole contact composition 3 NO
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50 Hz; Power circuit: <= 300 V DC
[Ie] rated operational current

40 A 60 °C) la <= 440 V AC-3 for power circuit
60 A 60 °C) la <= 440 V AC-1for power circuit
40 A 60 °C) la <= 440 V AC-3e for power circuit

Motor power kW

11 kW at 220...230 V c.a. 50 Hz (AC-3)
18,5 kW at 380...400 V c.a. 50 Hz (AC-3)
22 kW at 415...440 V c.a. 50 Hz (AC-3)
22 kW at 500 V c.a. 50 Hz (AC-3)
30 kW at 660...690 V c.a. 50 Hz (AC-3)
9 kW at 400 V c.a. 50 Hz (AC-4)
11 kW at 220...230 V c.a. 50 Hz (AC-3e)
18,5 kW at 380...400 V c.a. 50 Hz (AC-3e)
22 kW at 415...440 V c.a. 50 Hz (AC-3e)
22 kW at 500 V c.a. 50 Hz (AC-3e)
30 kW at 660...690 V c.a. 50 Hz (AC-3e)

Product Weight 0,85 kg
Average impedance 1,5 mOhm - Ith 60 A 50 Hz for power circuit
[Ui] Rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified
[Uimp] Rated impulse withstand voltage 6 kV conforming to SR EN 60947
Power dissipation per pole 2,4 W AC-3; 5,4 W AC-1; 2,4 W AC-3e
Front cover With
Mounting support Plate; Rail
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 10 A la <60 °C for signalling circuit; 60 A la <60 °C for power circuit;
Mechanical durability 6 Mcycles
Connections - terminals

Screw terminal control circuit 2 cable(s) 1…2,5 mm²flexible with cable end
Screw terminal control circuit 1 cable(s) 1…4 mm²flexible without
Screw terminal control circuit 2 cable(s) 1…4 mm²flexible without
Screw terminal control circuit 1 cable(s) 1…4 mm²flexible with
Screw terminal control circuit 1 cable(s) 1…4 mm²solid without
Screw terminal control circuit 2 cable(s) 1…4 mm²solid without
Circuit electric screw connection 1 cable(s) 1…35 mm²flexible without
Circuit electric screw connection 2 cable(s) 1…25 mm²flexible without
Circuit electric screw connection 1 cable(s) 1…35 mm²flexible with
Circuit electric screw connection 2 cable(s) 1…25 mm²flexible with
Circuit electric screw connection 1 cable(s) 1…35 mm²solid without
Circuit electric screw connection 2 cable(s) 1…25 mm²solid without

Tightening torque 8 N.m electrical circuit - turned on EverLink connectors with BTR screw - cable 25… 35 mm² hexagonal 4 mm; 5 N.m electrical circuit - turned on EverLink connectors with BTR screw - cable 1… 25 mm² hexagonal 4 mm
Operating time

4...19 ms opening
12...26 ms closing

Safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Standards

EN/IEC 60947-4-1
SR EN 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC 60335-1

Product certifications

UL
CSA
CCC
EAC
KC
LROS (Lloyds register of shipping)
DNV-GL
RINA
BV

Irms rated making capacity

800 A at 440 V for power circuit conforming to SR EN 60947
140 A AC for signalling circuit conforming to SR EN 60947-5-1
250 A DC for signalling circuit conforming to SR EN 60947-5-1

Rated breaking capacity 800 A at 440 V for power circuit conforming to SR EN 60947
Pollution degree 3
Operating altitude 0...3000 m
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -40…60 °C; 60…70 °C with derating
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Height 122 mm
Width 55 mm
Depth 120 mm
Associated fuse rating

10 A gG for signalling circuit conforming to SR EN 60947-5-1
80 A gG la <= 690 V coordination type 1 for power circuit
80 A gG la <= 690 V coordination type 2 for power circuit

Protective treatment TH conforming to IEC 60068-2-30
IP degree of protection

IP20 front face conforming to SR EN 60529

Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed:4 Gn, 5...300 Hz; Shocks contactor closed:15 Gn pentru 11 ms; Shocks contactor open:10 Gn pentru 11 ms
Maximum operating rate

3600 cyc/h 60 °C

Control circuit voltage limits

0.3...0.6 Uc -40…70 °C:drop-out DC 50 Hz
0,8...1,1 Uc -40…60 °C:operational DC 50 Hz
1...1.1 Uc 60…70 °C:operational DC 50 Hz

Inrush power in VA

160 VA 50 Hz 0,75 20 °C)

Hold-in power consumption in VA

15 VA 50 Hz 0,3 20 °C)

Auxiliary contacts type

Type mechanically linked 1 NO + 1 NC conforming to SR EN 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz
Non-overlap time

1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact

Overvoltage Category CAT III
We found other products you might like!

 

Netopia visa mastercard D&R Online Store Cromstat Software Fedex
Solutionarea online a litigilor Solutionarea alternativa a litigilor
Copyright © 2021-2024 - D & R ONLINE STORE S.R.L - RO44714842 - J35/3182/2021. All rights reserved.