We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
SCHNEIDER Electric - TeSys Deca Contactor, 3P (3 NO), AC-3/AC-3e, 440 V 9 A, 24 V DC coil, IP20
| Manufacturer | SCHNEIDER Electric |
|---|---|
| Manufacturer code | LC1D09BL |
| Order Unit | Pce |
| Range | TeSys; TeSys Deca |
| Product Name | TeSys D; TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive loadMotor control |
| Utilisation category | AC-3 |
| Power pole contact composition | 3 NO |
| Poles description | 3P |
| [uc] Control Circuit Voltage | 24 V DC |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC |
| [Ie] rated operational current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) |
| Motor power HP (UL / CSA) | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors |
| Control circuit type | DC low consumption |
| Product Weight | 0.48 kg |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| [Ui] Rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified |
| [Uimp] Rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Power dissipation per pole | 1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e |
| Front cover | With |
| Mounting support | Plate; Rail |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V; 2 Mcycles 9 A AC-3 at Ue <= 440 V; 2 Mcycles 9 A AC-3e at Ue <= 440 V |
| Connections - terminals | Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end |
| Tightening torque | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
| Operating time | 65.45...88.55 ms closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
| Standards | CSA C22.2 No 14 |
| Product certifications | GL |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| Operating altitude | 0...3000 m |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…60 °C; 60…70 °C with derating |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 95 mm |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms |
| Maximum operating rate | 3600 cyc/h 60 °C |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.1...0.3 Uc (-40…70 °C):drop-out DC |
| Time constant | 40 ms |
| Inrush power in W | 2.4 W (at 20 °C) |
| Hold-in power consumption in W | 2.4 W at 20 °C |
| Auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
| Signalling circuit frequency | 25...400 Hz |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact |
| Overvoltage Category | CAT III |