More Information
Manufacturer SCHNEIDER Electric
Manufacturer code LC1D150M7
Order Unit Pce
Range TeSys
Product Name TeSys D; TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control; Resistive load
Utilisation category

AC-3
AC-4
AC-1

Power pole contact composition 3 NO
Poles description 3P
[uc] Control Circuit Voltage 220 V AC 50/60 Hz
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz; Power circuit: <= 300 V DC
[Ie] rated operational current

200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

Motor power kW

40 kW at 220...230 V AC 50/60 Hz (AC-3)
75 kW at 380...400 V AC 50/60 Hz (AC-3)
80 kW at 415...440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660...690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
22 kW at 400 V AC 50/60 Hz (AC-4)

Motor power HP (UL / CSA)

40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
125 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Control circuit type AC at 50/60 Hz
Product Weight 2.5 kg
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] Rated insulation voltage Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1
[Uimp] Rated impulse withstand voltage 8 kV conforming to IEC 60947
Power dissipation per pole 24 W AC-1; 13.5 W AC-3
Front cover With
Mounting support Rail; Plate
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Mechanical durability 8 Mcycles
Electrical durability 0.85 Mcycles 150 A AC-3 at Ue <= 440 V; 1 Mcycles 200 A AC-1 at Ue <= 440 V
Connections - terminals

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end
Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end
Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end
Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end
Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end
Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end

Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Operating time

20...35 ms closing
40...75 ms opening

Safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Standards

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

Product certifications

CCC
LROS (Lloyds register of shipping)
GL
GOST
RINA
CSA
BV
UL
DNV
UKCA

Irms rated making capacity

140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity 1400 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Operating altitude 0...3000 m
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -40…60 °C; 60…70 °C with derating
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Height 158 mm
Width 120 mm
Depth 136 mm
Associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
250 A gG at <= 690 V coordination type 2 for power circuit

Protective treatment TH conforming to IEC 60068-2-30
IP degree of protection

IP20 front face conforming to IEC 60529

Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor closed: 15 Gn for 11 ms; Shocks contactor open: 6 Gn for 11 ms
Maximum operating rate

1200 cyc/h 60 °C

Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits

0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1...1.15 Uc (55…70 °C):operational AC 50/60 Hz

Inrush power in VA

280…350 VA 60 Hz cos phi 0.9 (at 20 °C)
280…350 VA 50 Hz cos phi 0.9 (at 20 °C)

Hold-in power consumption in VA

2…18 VA 60 Hz cos phi 0.9 (at 20 °C)
2…18 VA 50 Hz cos phi 0.9 (at 20 °C)

Heat dissipation 3…4.5 W at 50/60 Hz
Auxiliary contacts type

Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz
Non-overlap time

1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact