SCHNEIDER Electric - Auxiliary contact block, TeSys Deca, 3NO + 1NC, front mounting, screw clamp terminals

Lei 54.00 Lei 45.38
In stock
Only 10 left
SKU
LADN31
Free shipping for orders over 500 lei
Free shipping applies to cities without additional kilometers or heavy/high volume products
Write Your Own Review
You're reviewing:SCHNEIDER Electric - Auxiliary contact block, TeSys Deca, 3NO + 1NC, front mounting, screw clamp terminals
More Information
Manufacturer SCHNEIDER Electric
Manufacturer code LADN31
Order Unit Pce
Range TeSys; TeSys Deca
Product Name TeSys D; TeSys Deca
Product or component type Auxiliary contact block
Range compatibility

TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1D

Mounting location Front
Pole contact composition 3 NO + 1 NC
Device short name LADN
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25...400 Hz
Product Weight 0.05 kg
[Ui] Rated insulation voltage 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA
[Ith] conventional free air thermal current 10 A (at 60 °C)
Mechanical durability 30 Mcycles
Connections - terminals

Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end

Tightening torque 1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2
Standards

EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5

Product certifications

CB
UL
CSA
CCC
EAC
UKCA

Irms rated making capacity

140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1

Permissible short-time rating

100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 ms

Operating altitude 3000 m
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -5…60 °C
Protection type GG fuse 10 A
Minimum switching current 5 mA
Minimum switching voltage 17 V
Height 48 mm
Width 44 mm
Depth 42 mm
Protective treatment TH conforming to IEC 60068
IP degree of protection IP20 conforming to IEC 60529
Non-overlap time

1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contact