SCHNEIDER Electric - TeSys D Contactor, 3P, 12A, AC-3 440V, aux 1NO+1NC, 230V, 50Hz

Lei 97.00 Lei 81.51
In stock
Only 4 left
SKU
LC1D12P5
Free shipping for orders over 500 lei
Free shipping applies to cities without additional kilometers or heavy/high volume products
Write Your Own Review
You're reviewing:SCHNEIDER Electric - TeSys D Contactor, 3P, 12A, AC-3 440V, aux 1NO+1NC, 230V, 50Hz
More Information
Manufacturer SCHNEIDER Electric
Manufacturer code LC1D12P5
Order Unit Pce
Range TeSys; TeSys Deca
Product Name TeSys D; TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control; Resistive load
Utilisation category

AC-1
AC-3
AC-4
AC-3e

Power pole contact composition 3 NO
Poles description 3P
[uc] Control Circuit Voltage 230 V c.a. 50 Hz
[Ue] rated operational voltage Power circuit: <= 690 V AC 50 Hz; Power circuit: <= 300 V DC
[Ie] rated operational current

25 A 60 °C) at <= 440 V AC-1 for power circuit
12 A 60 °C) at <= 440 V AC-3 for power circuit
12 A 60 °C) at <= 440 V AC-3e for power circuit

Motor power kW

3 kW at 220...230 V c.a. 50 Hz (AC-3)
5,5 kW at 380...400 V c.a. 50 Hz (AC-3)
5,5 kW at 415...440 V c.a. 50 Hz (AC-3)
7,5 kW at 500 V c.a. 50 Hz (AC-3)
7,5 kW at 660...690 V c.a. 50 Hz (AC-3)
3,7 kW at 400 V c.a. 50 Hz (AC-4)
3 kW at 220...230 V c.a. 50 Hz (AC-3e)
5,5 kW at 380...400 V c.a. 50 Hz (AC-3e)
5,5 kW at 415...440 V c.a. 50 Hz (AC-3e)
7,5 kW at 500 V c.a. 50 Hz (AC-3e)
7,5 kW at 660...690 V c.a. 50 Hz (AC-3e)

Product Weight 0,325 kg
[Uimp] Rated impulse withstand voltage 6 kV conform SR EN 60947
Front cover With
Mounting support Plate; Rail
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 10 A at <60 °C for signalling circuit; 25 A la <60 °C for power circuit
Mechanical durability 6 Mcycles
Electrical durability 2 Mcycles 12 A AC-3 at Ue <= 440 V; 0,8 Mcycles 25 A AC-1 at Ue <= 440 V; 2 Mcycles 12 A AC-3e at Ue <= 440 V
Connections - terminals

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…2,5 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2,5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end

Tightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Operating time

4...19 ms opening
12...22 ms closing

Safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Standards

EN/IEC 60947-1
IEC 60947-4-1
SR EN 60947-5-1
SR EN 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC 60335-1

Product certifications

UL
CSA
CCC
EAC
KC
LROS (Lloyds register of shipping)
DNV-GL
RINA
BV
UKCA

Irms rated making capacity

250 A at 440 V for power circuit conforming to SR EN 60947
140 A AC for signalling circuit conforming to SR EN 60947-5-1
250 A DC for signalling circuit conforming to SR EN 60947-5-1

Rated breaking capacity 250 A at 440 V for power circuit conforming to SR EN 60947
Pollution degree 3
Operating altitude 0...3000 m
Ambient air temperature for storage -60…80 °C
Ambient air temperature for operation -40…60 °C; 60…70 °C with derating
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Height 77 mm
Width 45 mm
Depth 86 mm
Associated fuse rating

10 A gG for signalling circuit conforming to SR EN 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit

Protective treatment TH conforming to IEC 60068-2-30
IP degree of protection

IP20 front face conforming to SR EN 60529

Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms
Maximum operating rate

3600 cyc/h 60 °C

Coil technology Without built-in suppressor module
Control circuit voltage limits

0.3...0.6 Uc (-40…70 °C):drop-out AC 50 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
1...1.1 Uc (60…70 °C):operational AC 50 Hz

Inrush power in VA

70 VA 50 Hz 0,75 20 °C)

Hold-in power consumption in VA

7 VA 50 Hz 0,3 20 °C)

Heat dissipation 2…3 W at 50 Hz
Auxiliary contacts type

Type mechanically linked 1 NO + 1 NC conforming to SR EN 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz
Non-overlap time

1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact