We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
VICTRON ENERGY - Multi RS Solar 48/6000/100-450/80 1 tracker
Pretul afisat este cu 9% TVA pentru persoane fizice sau institutii de stat. Pentru persoane juridice se va recalcula pretul cu 19% TVA dupa plasarea comenzii.
Multi RS Solar
Hybrid Inverter/Charger
The Multi RS Solar 48/6000 is a 48V 6kVA Inverter/Charger with 450VDC 4kWp PV input.
Thanks to high frequency technology and a new design this powerful inverter weighs only 11kg. In addition to this it has an excellent efficiency, low standby power, and a very quiet operation.
The display reads battery, inverter and solar parameters. The same parameters can be accessed with a smartphone or other Bluetooth enabled device, using the VictronConnect app.
Manufacturer | VICTRON ENERGY |
---|---|
Manufacturer code | PMR482602000 |
GTIN code | 8719076054474 |
Order Unit | Pce |
Output Voltage | 230V |
Battery voltage | 48V |
Weight Kg | 12 Kg |
Dimensions (h x w x d) | 425 x 440 x 125 mm |
Standards | Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 Emission, Immunity: EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 1) Minimum start-up voltage is 41 V. Inverter shutdown can be set as low as 32 VDC, but may shut down on low AC output voltage (due to load). Over-voltage disconnect is 65.5 V. 2) Can be adjusted to 60 Hz 3) MPPT operating range is also constrained by battery voltage - PV VOC should not exceed 8x battery float voltage, e.g. a 50 V battery voltage maximum should have 400 V maximum PV array. – see product manual for further information. 4) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35 VDC and 1 A up to 70 VDC 5) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) Solar earth leakage 6) Connection to a GX device (i.e. Cerbo GX) must be made via the VE.Can interface. The VE.Direct interface is for connection to the GlobalLink 520, and to a computer, using a VE.Direct to USB to cable. 7) The Charger set-point (float and absorption) can be set to max 60 V. The output voltage at the charger terminals can be higher, due to temperature compensation as well as compensation for voltage drop over the battery cables. The maximum output current is reduced on a linear basis from full current at 60 V to 5A at 62 V. The equalization voltage can be set to max 62V, the equalization current percentage can be set to max 6%. |