SCHNEIDER Electric - Variable speed drive, Altivar Process ATV900, ATV930, 4 kW, 400/480 V, with braking unit, IP21

Lei 5,547.00 Lei 4,661.34
In stock
Only 1 left
SKU
ATV930U40N4
Free shipping for orders over 500 lei
Free shipping applies to cities without additional kilometers or heavy/high volume products
Write Your Own Review
You're reviewing:SCHNEIDER Electric - Variable speed drive, Altivar Process ATV900, ATV930, 4 kW, 400/480 V, with braking unit, IP21
More Information
Manufacturer SCHNEIDER Electric
Manufacturer code ATV930U40N4
Order Unit Pce
Range of product Altivar Process ATV900
Product or component type Variable speed drive
Device short name ATV930
Device application Industrial application
Product destination Synchronous motors; Asynchronous motors
Variant Standard version; With braking chopper
[Us] rated supply voltage 380...480 V - 15...10 %
Power dissipation in W Natural convection: 33 W at 380 V, switching frequency 4 kHz; Forced convection: 97 W at 380 V, switching frequency 4 kHz
Discrete input number 10
Analogue input number 3
Discrete output number 2
Switching frequency 2...16 kHz adjustable; 4...16 kHz with derating factor
Transmission rate

10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

Communication port protocol

Modbus serial
Modbus TCP
EtherNet/IP

Local signalling

Local diagnostic: 3 LED (mono/dual colour)
Embedded communication status: 5 LED (dual colour)
Communication module status: 2 LED (dual colour)
Presence of voltage: 1 LED (red)

Electrical connection

Control: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16
Line side: screw terminal 2.5...6 mm²/AWG 14...AWG 10
Motor: screw terminal 2.5...6 mm²/AWG 14...AWG 10
DC bus: screw terminal 2.5...6 mm²/AWG 14...AWG 10

Marking CE
Height mm 350 mm
Depth mm 206 mm
Width in mm 144 mm
Net weight 4.6 kg
Product certifications

CSA
UL
TÜV

Standards

UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1

IP degree of protection

IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529

Environmental characteristics (UV)

Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3

Pollution degree 2
Ambient air temperature for operation -15…50 °C (without derating); 50…60 °C (with derating factor)
Ambient air temperature for storage -40…70 °C
Operating altitude <= 1000 m without derating; 1000...4800 m with current derating 1 % per 100 m
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Vibration resistance

1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
EMC filter

Integrated with 50 m conforming to EN/IEC 61800-3 category C2
Integrated with 150 m conforming to EN/IEC 61800-3 category C3

Degree of protection UL type 1 conforming to UL 508C
Type of cooling Forced convection
Supply frequency 50...60 Hz +/- 5 %
Motor power kW

4 kW (normal duty)
3 kW (heavy duty)

Motor power hp

5 hp normal duty
4 hp heavy duty

Line current

7.6 A at 380 V (normal duty)
6.7 A at 480 V (normal duty)
6 A at 380 V (heavy duty)
5.4 A at 480 V (heavy duty)

Prospective line Isc 50 kA
Apparent power

5.6 kVA at 480 V (normal duty)
4.5 kVA at 480 V (heavy duty)

Continuous output current

9.3 A at 4 kHz for normal duty
7.2 A at 4 kHz for heavy duty

Maximum transient current

11.2 A during 60 s (normal duty)
10.8 A during 60 s (heavy duty)

Asynchronous motor control profile

Optimized torque mode
Constant torque standard
Variable torque standard

Synchronous motor control profile

Permanent magnet motor
Synchronous reluctance motor

Speed drive output frequency 0.1…599 Hz
Nominal switching frequency 4 kHz
Safety function STO (safe torque off) SIL 3
Number of preset speeds 16 preset speeds
Option module

Slot A: communication module for Profibus DP V1
Slot A: communication module for Profinet
Slot A: communication module for DeviceNet
Slot A: communication module for EtherCAT
Slot A: communication module for CANopen daisy chain RJ45
Slot A: communication module for CANopen SUB-D 9
Slot A: communication module for CANopen screw terminals
Slot A/slot B/slot C: digital and analog I/O extension module
Slot A/slot B/slot C: output relay extension module
Slot B: 5/12 V digital encoder interface module
Slot B: analog encoder interface module
Slot B: resolver encoder interface module
communication module for Ethernet Powerlink

Output Voltage <= power supply voltage
Acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Braking to standstill By DC injection
txt_Protection type

Thermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive

Frequency resolution

Display unit: 0.1 Hz
Analog input: 0.012/50 Hz

Connector type 2 RJ45 for Ethernet IP/Modbus TCP on the control block; 1 RJ45 for Modbus serial on the control block
Physical interface 2-wire RS 485 for Modbus serial
Transmission frame RTU for Modbus serial
Exchange mode Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format 8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization No impedance for Modbus serial
Number of addresses 1…247 for Modbus serial
Method of access Slave Modbus TCP
txt_Supply

External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection

txt_Analogue input type

AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits

txt_Discrete input type

DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm

txt_Input compatibility

DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2

txt_Discrete input logic

Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)

Analogue output number 2
Analogue output type

Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits

txt_Discrete output type

Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA

Sampling duration

2 ms +/- 0.5 ms (DI1...DI8) - discrete input
5 ms +/- 1 ms (DI7, DI8) - pulse input
1 ms +/- 1 ms (AI1, AI2, AI3) - analog input
5 ms +/- 1 ms (AQ1, AQ2) - analog output

Accuracy

+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output

Linearity error

AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output

Maximum switching current

Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

Relay output number 3
Relay output type

Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles

Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Isolation Between power and control terminals
Variable speed drive application selection

Food and beverage processing Mixer
Food and beverage processing Conveyor
Food and beverage processing Shredder
Hoisting Process crane
Marine Thruster
Marine Winch
Material working (wood, ceramic, stone, pvc, metal) Press
Material working (wood, ceramic, stone, pvc, metal) Extruder
Mining mineral and metal Other application
Oil and gas Drilling rig
Oil and gas Progressive cavity pump
Oil and gas Rod pump
Oil and gas Swapping pump
Oil and gas Compressor for regasification
Oil and gas Separator
Oil and gas Other application
Water and waste water Separator

Power range

4…6 kW at 380…440 V 3 phases
4…6 kW at 480…500 V 3 phases

Mounting mode Wall mount
Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Volume of cooling air 38 m3/h
Operating position Vertical +/- 10 degree
Maximum THDI <48 % full load conforming to IEC 61000-3-12
txt_Electromagnetic compatibility

Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6