SCHNEIDER Electric - TeSys K contactor, 3P, 9A, AC-3, <= 440V, aux 1NO, coil 230V, 50Hz
Manufacturer | SCHNEIDER Electric |
---|---|
Manufacturer code | LC1K0910P5 |
Order Unit | Pce |
Range | TeSys |
Product Name | TeSys K |
Product or component type | Contactor |
Contactor application | Resistive load; Motor control |
Utilisation category | AC-1 |
Power pole contact composition | 3 NO |
Poles description | 3P |
[uc] Control Circuit Voltage | 230 V AC 50 Hz |
[Ue] rated operational voltage | 690 V AC 50 Hz |
[Ie] rated operational current | 9 A at <= 440 V AC AC-3 for power circuit |
Motor power kW | 2.2 kW at 220...230 V AC 50 Hz AC-3 |
Control circuit type | AC at 50 Hz |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
[Ui] Rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V conforming to UL 60947-4-1; Power circuit: 600 V conforming to CSA C22.2 No 60947-4-1 |
Mounting support | Rail; Plate |
Auxiliary contact composition | 1 NO |
[Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signalling circuit |
Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue <= 440 V; 0.18 Mcycles 20 A AC-1 at Ue <= 440 V |
Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid |
Tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Operating time | 10...20 ms coil de-energisation and NO opening |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
Standards | IEC 60947-4-1 |
Product certifications | UL |
Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 |
Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947 |
Operating altitude | 2000 m without derating |
Ambient air temperature for storage | -50…80 °C |
Minimum switching current | 5 mA for signalling circuit |
Minimum switching voltage | 17 V for signalling circuit |
Height | 58 mm |
Width | 45 mm |
Depth | 57 mm |
Associated fuse rating | 25 A gG at <= 440 V for power circuit |
Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
IP degree of protection | IP20 conforming to VDE 0106 |
Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
Mechanical robustness | Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Maximum operating rate | 3600 cyc/h |
Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) |
Inrush power in VA | 30 VA (at 20 °C) |
Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
Heat dissipation | 1.3 W |
Auxiliary contacts type | Type instantaneous 1 NO |
Signalling circuit frequency | <= 400 Hz |
Non Overlap Distance | 0.5 mm |
Overvoltage Category | CAT III |
-